Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(2): 140-144, 2024 Feb 15.
Artículo en Chino | MEDLINE | ID: mdl-38385224

RESUMEN

Objective: To analyze the effectiveness of binocular loupe assisted mini-lateral and medial incisions in lateral position for the release of elbow stiffness. Methods: The clinical data of 16 patients with elbow stiffness treated with binocular loupe assisted mini-internal and external incisions in lateral position release between January 2021 and December 2022 were retrospectively analyzed. There were 9 males and 7 females, aged from 19 to 57 years, with a median age of 33.5 years. Etiologies included olecranon fracture in 6 cases, elbow dislocation in 4 cases, medial epicondyle fracture in 2 cases, radial head fracture in 4 cases, terrible triad of elbow joint in 2 cases, supracondylar fracture of humerus in 1 case, coronoid process fracture of ulna in 1 case, and humerus fracture in 1 case, with 5 cases presenting a combination of two etiologies. The duration of symptoms ranged from 5 to 60 months, with a median of 8 months. Preoperatively, 12 cases had concomitant ulnar nerve numbness, and 6 cases exhibited ectopic ossification. The preoperative range of motion for elbow flexion and extension was (58.63±22.30)°, the visual analogue scale (VAS) score was 4.3±1.6, and the Mayo score was 71.9±7.5. Incision lengths for both lateral and medial approaches were recorded, as well as the occurrence of complications. Clinical outcomes were evaluated using Mayo scores, VAS scores, and elbow range of motion both preoperatively and postoperatively. Results: The lateral incision lengths for all patients ranged from 3.0 to 4.8 cm, with an average of 4.1 cm. The medial incision lengths ranged from 2.4 to 4.2 cm, with an average of 3.0 cm. The follow-up duration ranged from 6 to 19 months and a mean of 9.2 months. At last follow-up, 1 patient reported moderate elbow joint pain, and 3 cases exhibited residual mild ulnar nerve numbness. The other patients had no complications such as new heterotopic ossification and ulnar nerve paralysis, which hindered the movement of elbow joint. At last follow-up, the elbow range of motion was (130.44±9.75)°, the VAS score was 1.1±1.0, and the Mayo score was 99.1±3.8, which significantly improved when compared to the preoperative ones ( t=-12.418, P<0.001; t=6.419, P<0.001; t=-13.330, P<0.001). Conclusion: The binocular loupe assisted mini-lateral and medial incisions in lateral position integrated the advantages of traditional open and arthroscopic technique, which demonstrated satisfying safety and effectivity for the release of elbow contracture, but it is not indicated for patients with posterior medial heterolateral heterotopic ossification.


Asunto(s)
Lesiones de Codo , Articulación del Codo , Artropatías , Osificación Heterotópica , Masculino , Femenino , Humanos , Adulto , Codo , Estudios Retrospectivos , Hipoestesia/etiología , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Articulación del Codo/cirugía , Rango del Movimiento Articular , Osificación Heterotópica/etiología
2.
J Orthop Surg Res ; 18(1): 835, 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37926844

RESUMEN

BACKGROUND: Tension band wiring (TBW) has conventionally been used for the open reduction and internal fixation of the patella. However, it suffers from distinct disadvantages such as large incision, implant irritation, and need for subsequent implant removal. Here, we propose a novel technique using closed reduction and percutaneous fixation with three cannulated screws (TCS), which may be an alternative to this established conventional technique. Although some researchers have proposed alternative methods including closed reduction and cannulated screw fixation, with or without additional wires through the screws, and arthroscopic-assisted reduction and fixation, there are few studies that focus on the biomechanical stability of percutaneous fixation using only cannulated screws. Thus, the purpose of this study was to evaluate TCS versus TBW for simple transverse patellar fractures in cadaveric and patients' level, aiming to determine whether TCS show superiority over TBW in terms of biomechanical stability in a cadaveric study with benign clinical feasibility and outcomes in patients. METHODS: We conducted a cadaveric study with 15 knee specimens that had simple transverse patellar fractures. We used two fixation techniques: TBW (group A, n = 6) and TCS (group B, n = 9). We applied sinusoidal forces (25 N-125 N) at 1/5 Hz and 90° knee flexion to simulate knee movement. We compared the displacements at the fracture site between the two groups. We also used the same technique in a total of 23 patients and followed up them for at least 1 year. RESULTS: TCS demonstrated favourable biomechanical stability in the cadaveric study. The technique also performed excellently in terms of postoperative pain, knee function recovery, and complication rates during the follow-up period. CONCLUSIONS: The technique provides a surgical treatment option with small incisions, minimal soft tissue irritation, and possibly lower removal rate of bothersome material.


Asunto(s)
Fracturas Óseas , Traumatismos de la Rodilla , Humanos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Hilos Ortopédicos , Rótula/cirugía , Traumatismos de la Rodilla/cirugía , Cadáver
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...